Controlling Dust Exposures in Longwall Mining Utilizing a Simple Barrier
Document Type
Article
Publication Date
12-2009
Abstract
The United States coal mining industry has traditionally experienced difficulty in controlling dust levels below the occupational exposure limit. While improvements in face ventilation and water spray nozzles have decreased dust exposures, approximately eight percent of experienced coal miners are still developing Coal Worker’s Pneumoconiosis. This investigation tested the feasibility of enhancing existing engineering dust controls by mounting a simple barrier on a longwall shearer that separated the operators from the cutting drums. The barrier was constructed and tested above ground at the National Institute for Occupational Safety and Health Pittsburgh Research Laboratory longwall gallery test facility. A 96-percent reduction of respirable dust occurred at the headgate sampling position when tested at 2.4 m/sec (480 ft/min). The average dust level decreased from 39 mg/m3 to 1.5 mg/m3by utilizing the barrier.
Abstract © SME. Abstract source here.
Source Publication
Mining Engineering
Recommended Citation
Sweeney, D. D., & Slagley, J. M. (2009, December). Controlling dust exposures in longwall mining utilizing a simple barrier. Mining Engineering, 60(12), 58–61.
Comments
Copyright © 2009 Society for Mining, Metallurgy and Exploration. All Rights Reserved.
This article is accessible by subscription only. Current AFIT faculty, students and staff may access the full-text of the article at ProQuest by clicking here. [HTML].
Related AFIT thesis by Daniel Sweeney: AFIT-GIH-ENV-09-M03. Master of Science in Industrial Hygiene, March 2009.