Experimental Investigation of Stepped Tip Gap Effects on the Performance of a Transonic Axial-Flow Compressor Rotor

Document Type

Conference Proceeding

Publication Date

1997

Abstract

The effects of stepped tip gaps and clearance levels on the performance of a transonic axial-flow compressor rotor were experimentally determined. A two-stage compressor with no inlet guide vanes was tested in a modern transonic compressor research facility. The first-stage rotor was unswept and was tested for an optimum tip clearance with variations in stepped gaps machined into the casing near the aft tip region of the rotor. Nine casing geometries were investigated consisting of three step profiles at each of three clearance levels. For small and intermediate clearances, stepped tip gaps were found to improve pressure ratio, efficiency, and flow range for most operating conditions. At 100% design rotor speed, stepped tip gaps produced a doubling of mass flow range with as much as a 2.0% increase in mass flow and a 1.5% improvement in efficiency. This study provides guidelines for engineers to improve compressor performance for an existing design by applying an optimum casing profile. Abstract © ASME

Comments

Copyright © 1997 American Society of Mechanical Engineers

The "Link to Full Text" button on this page loads the freely-accessible conference paper, hosted at ASME. The publisher retains permissions to re-use and distribute this publication. Use of the linked article is subject to copyrights of the publisher.

DOI

10.1115/97-GT-007

Source Publication

Proceedings of the ASME Turbo Expo

Share

COinS