Characterization of miniaturized RLC resonators made of biodegradable materials for wireless implant applications
Document Type
Article
Publication Date
2013
Abstract
As a first step toward the ultimate goal of making fully biodegradable implants for in vivo operation, miniaturized radio frequency (RF)-driven resistor–inductor–capacitor (RLC) resonators made of biodegradable materials are fabricated and characterized. The resonators made of biodegradable metals (magnesium, iron, Mg- and Fe-alloys) are fabricated by electric discharge machining, while the resonators made of biodegradable conducting polymer composites (polylactide–polypyrrole, PLLA–PPy and poly(ɛ-caprolactone)–polypyrrole, PCL–PPy) are fabricated by compression molding combined with laser-cutting. The unloaded resonant frequency funloaded and unloaded quality factor Qunloaded of the RLC resonators are obtained from capacitive coupling and inductive coupling measurements. funloaded and Qunloaded are found to be 0.5–1 GHz and 8–410 for the metal resonators, and 2.0–3.4 GHz and 6–19 for the polymer resonators, respectively. The RF conductivity and RF relative permeability of the materials used to fabricate the RLC resonators are evaluated from capacitive coupling measurements combined with finite element simulations. Finally, the performance in a human body-like environment is evaluated. Even if largely attenuated, the resonance peak remained detectable with 6 mm of muscle/fat tissue placed between the RLC resonator and the measurements coil, for both metal and polymer resonators. As a conclusion, all the investigated biodegradable materials can be suitable to fabricate passive wireless communication devices for biosensors implanted inside the body. At this state of the research, magnesium is the most promising candidate to fabricate RLC resonators, since it combines high conductivity (high Q) and promising biodegradation properties. Alternatively, the Mg-alloy could be of interest if faster biodegradation and higher mechanical performance of the implant is required. On the other hand, the biodegradable conducting polymers PCL–PPy and PLLA–PPy are also of interest because of their light weight, higher flexibility in the fabrication process, compatibility with magnetic resonance imaging and transparency to X-rays.
DOI
10.1016/j.sna.2012.08.039
Source Publication
Sensors and Actuators A: Physical
Recommended Citation
Clémentine M. Boutry, Hengky Chandrahalim, Patrick Streit, Michael Schinhammer, Anja C. Hänzi, and Christofer Hierold, "Characterization of miniaturized RLC resonators made of biodegradable materials for wireless implant applications," Sens. Actuators A, Phys., 189, 2013, pp. 344-355.
Comments
This is a subscription-access article. The "Link to Full Text" button at the right of this screen is for AFIT students, faculty and staff.
Readers outside of AFIT will need to access the article through their own digital subscription to Sensors and Actuators A. https://doi.org/10.1016/j.sna.2012.08.039